Novelties

ArabLab 2019

  • Visit us at:

    ArabLab 2019
    Dubai, March 12-14 2019

Safety timer for automatic LN2 - niveau level controller

  • Safety timer for automatic LN2 - niveau level controller

Pressure build-up for LN2 tank using N2 gas bottles or N2 central gas supply

Many LN2 storage containers made of aluminium or stainless steel do not have internal pressure attachment. This means that, especially after filling an aluminium LN2 container for the first time, the user has to wait for several hours before sufficient pressure for transferring the liquid is obtained. Additionally, extraction volumes are limited for these LN2 containers without internal pressure attachment, as only a limited gas volume is available for excess pressure in completely filled containers. In order to be able to transfer LN2 continuously or, in larger quantities, from the LN2 containers, an external pressuriser can be connected to the transfer siphon of the LN2 container.

The new cold traps catalog A16 from KGW Isotherm

Dewar vessel out of stainless steal type JUNO

Characteristics

Area of application

More Information at Dewar vessel out of stainless steal type JUNO

Liquid Nitrogen Container made of Aluminium Type ALU-CD-DMT With Dipper for Dermatology

Description of Aluminium Dewar vessel Type DMT

More Information at Liquid Nitrogen Container made of Aluminium Type ALU-CD-DMT With Dipper for Dermatology

Cold Traps made of Stainless steel

Construction, Operation and Principles

Cold traps are used in conjunction with vacuum pumps to collect condensation produced from humidity or solvents and these cold traps can be used for many different tasks. The most common application is collecting condensation produced from humidity or solvents from rotating discs, vacuum pumps or high vacuum systems that use oil diffusion or turbo-molecular pumps. In this case a common coolant such as liquid nitrogen (LN2) or dry-ice (CO2) with acetone is normally used.

More Information in Technical Datasheet

Mobile Rack Type Easy Frame for Reaction Vessels

Advantages of the rack type Easy Frame
The mobile rack type Easy Frame consists of

More Information at Racks for Reaction Vessels

NLK Apparatus according EN 459-2 / DIN 1060 Part 3


Examination of the reactivityof fine lime while slaking effects via measuring the incipientrise of temperature subject to the duration of reaction (wet slaking curve, NLK). Basis of apparatus and measuring system is EN 459-2.

More Information at NLK apparatus with Dewar